Color Coded Rings, Large, 25 pcs/box — Green | ErgoDenta 5641G
ErgoDenta ApS · #5641G · source
Autoclavable, heat-resistant colour-code rings that let you identify and organise instruments at a glance. The large size fits extraction forceps and wider handles. 25 rings per box. Colour: Green.
Color-Code Rings — organize dental instruments by colour, procedure or clinician
Autoclavable silicone rings that slide onto any instrument handle. 2 sizes, 8 colours. Use them to encode procedure family, clinician, or sterilization week.
Two sizes — pick by handle width
- Small (50 pcs/box) — fits ~6–8mm hand-instrument handles. Scalers, curettes, probes, mirrors, composite instruments.
- Large (25 pcs/box) — fits ~8–11mm wider handles. Extraction forceps, elevators, surgical handles.
Eight colours — code your system
- Black · Yellow · Green · Blue · Light Blue
- Lavender · Red · White
- Sold per-colour, or as a Mixed Box (8 colours, one box)
Common color-coding workflows
- By procedure — green=perio · blue=restorative · red=surgery · yellow=endo · white=diagnostic
- By clinician — one colour per doctor in multi-doctor practices
- By sterilization week — rotate weekly to prove cycle
Sterilization-safe
- Medical-grade silicone, autoclavable to 134°C
- Compatible with B-class, gravity, and pre-vacuum cycles
- Colour is integral to silicone — no fade, no peel, no leach
Box options — single colour or mixed
- Small single-colour box — 50 pcs, one colour
- Large single-colour box — 25 pcs, one colour
- Mixed Small Box (5651) — 8 colours × 25 pcs = 200 rings
- Mixed Large Box (5641) — 8 colours × 12 pcs = 96 rings
How to fit — 30 seconds per instrument
- Pick the colour for the family or clinician
- Stretch ring over the working end
- Slide down to the grip area
- Done — stays put through every cycle
Reprocessing Instructions
Important: ErgoDenta instruments are supplied NON-STERILE and must be cleaned, disinfected, and sterilized before first use and after each subsequent use. Step 1: Pre-Cleaning Rinse under cold running water immediately after use. Remove visible debris with a soft brush. Keep instruments moist until processing. Step 2: Automated Cleaning Washer-disinfector: pre-rinse cold, enzymatic wash 55°C/10 min, thermal disinfect 90°C/5 min, dry. Step 3: Inspect & Maintain Check for residual soil, corrosion, or damage. Lubricate hinged instruments with medical-grade lubricant. Step 4: Package Place in ISO 11607-compliant sterilization pouches or wraps. Arrange to prevent tip contact. Seal properly. Step 5: Sterilize Autoclave at 134°C (273°F) for min. 18 minutes, pre-vacuum cycle. Validate with chemical and biological indicators. Step 6: Store Store in a clean, dry, enclosed area. Verify packaging integrity before use. Re-sterilize if compromised.
Product Information
| Manufacturer | ErgoDenta ApS |
|---|---|
| Size | Large |
| Color | Green |
| Material | Medical-grade silicone |
| Autoclavable Temperature | 134°C |